What would you say if I ask for the causes the most contamination of products during the manufacture of pharmaceuticals? If you’re like me, 'people' was the first thought that came to mind. You and I both are right, in fact; people, raw materials, and water are one of the main contaminants of products according to most microbiologists.
However, air is another key source of contamination that most pharmaceutical facilities often ignore to take precaution from. Air particulate sampling or air monitoring is essential for Quality Control (QC) purposes especially in companies that manufacture pharmaceutical products in controlled areas or clean rooms with filtered air.
Well, what pharmacists, health care practitioners, and microbiologists refer to as air sampling can simply be defined as taking a correct measurement of the practical airborne bacteria, mold, yeast, spores and fungal cells which can be collectively referred to as bioburden in the surrounding air and it is the purpose of environmental monitoring.
The two main methods used to sample air are:
- Active air sampling/ monitoring
- Passive air sampling/ monitoring
Following is the difference between active and passive air sampling.
1. Active Air Sampling
This method is sometimes referred to as pumped sampling where the air in the controlled area is kinetically monitored during manufacturing. What this means is, over a specific time period, a microbial air sampler is used to continuously force an already established volume of air to pass over a petri dish that serves as the artificial medium containing an agar nutrient based test media.
Related: Human Generated Contamination in Cleanroom and its Control
The Petri dishes containing medium are then removed from the air sampler and directly incubated. Incubation allows the collected culture that is the microorganisms such as bacteria, fungi etc to grow into visible colonies that can be easily identified and analyzed through counting. This gives a clear indicator of how many viable microorganisms are there per cubic meter of air.
Advantages
- It allows for both qualitative and quantitative analysis of the sample
- Allows for faster results as devices used for this method allow for a shorter sampling period such as 10 minutes
- Ideal for controlled areas as they tend to have a low microbial concentration
Also referred to as diffusive air sampling, passive air sampling basically involves leaving settle plates or contact plates exposed to the air for a certain period of time to collect microbes that may settle onto the surfaces of the plates.
Just like in the active air sampling, the plates are then incubated to allow for the microorganisms that dropped onto the plates to grow into colonies that can accurately be analyzed.
Advantages- For starters, the method is inexpensive as it does not require a lot of equipment
- Offers average contamination levels over long sampling periods that could range from hours to months
- No supervision is required during the sampling period
- Its affordability makes it easy to sample various contamination hotspots at once
Both methods have their own advantages but none of the methods of air sampling given above is optional but both are mandatory because both of them give different information about the air in the classified area.
Related: Is Fungal Count Acceptable in Pharmaceutical Classified Area?
As I mentioned above in active air sampling we determine bioburden in 1 cubic meter area and we sample 1000 liters of air by air sampler while in passive air sampling we determine that how much microbes settle in 90 mm diameter surface of any equipment exposed in controlled area.
A lot of pharmaceutical professionals have confusion in air sampling that which one should be done among both of samplings. But all regulatory guidelines say that it is mandatory to sample and analyze the clean room area by both methods of air sampling for a complete air quality assessment.
what is the need for stratified sampling, why we are going for stratified sampling in pharmaceuticals
ReplyDeleteBoth are mandatory.
ReplyDeletesir please clear the main difference between both settle and active.
ReplyDeleteAlready written a separate article.
DeleteWhy air sampler required 1000 litre of air for grade A
ReplyDeleteTo measure 1 m3 area.
DeleteSir please tell calculation for measuring 1m3 area for 1000ltrs
ReplyDelete1 Liter of air is equal to 0.001 cubic meter thus we can calculate 1000*0.001=1cu meter
DeleteParticle Counters are measure in cubic feet in per minute hence 35.3147 Cubic Feet is equal to 35.3147 minutes data approx 36 min time is equal to 1000ltr or 1m3
In what time interval we can do these samplings?
ReplyDeleteWhat is the flow rate of active air sampler?