Recovery Factor Determination in Cleaning Validation : Pharmaguideline
  •   Pharmaguideline Courses Enroll Now
  • May 23, 2024

    Recovery Factor Determination in Cleaning Validation

    Recovery factor and its determination and calculation in cleaning validation of pharmaceutical manufacturing equipments.
    It is necessary to use recovery factor for accurate results in cleaning validation of pharmaceutical manufacturing equipment. Recovery factor is the recovery of swabbed material from the equipment to the solution.

    When we take a sample from the equipment with the cotton swab the entire API associated with the equipment is not removed by the swab and this error of recovery is managed by the recovery factor during the calculations in cleaning validation.

    Swab for Recovery
    A solution of known concentration of API is applied to the stainless steel plate of 10 cm2 and allow the plate to air dry. Swab the plate with the cotton swab and dissolve in a suitable diluent.

    Diluents should be prepared on the basis of the solubility of the active ingredient. Sonicate the cotton swab and diluents for 5 minutes to dissolve the content properly. Makeup the solution with the diluents to get the desired concentration as the standard solution is prepared.

    Mix the solution properly and analyze as per the method of analysis using HPLC, Ultra Violet spectrophotometer or titration. Calculate recovery factor by the following recovery factor formula:

    % Recovery = Area of swab sample solution x Standard dilution x 100
                             Area of the standard solution used x Sample dilution

    Recovery Factor =   100/ % Recovery

    Suppose the % recovery of any swab is 80% then recovery factor of that swab shall be 100/80=1.25. Results are multiplied by 1.25 to increase the results by 1.25 times that were lost during the swabbing. Recovery calculation should be done for both chemical and microbiological sampling in the same manner.

    FDA has suggested determining the % recovery of contaminants from the equipment surface in cleaning validation guidelines but the limit of recovery is not written clearly.
    WHO guidelines also say that there should be evidence of the proper recovery of the samples. According to WHO TRS 937 (page 133) a recovery of >80% is considered good.

    Get editable documentsView List

    1 comment: Post Yours! Read Comment Policy ▼

    1. Hii sir,

      This is very good information, but can we say whether which MOC is having better RF ?

      Best Regards,
      AJAY K

      ReplyDelete

    Please don't spam. Comments having links would not be published.


    Popular Categories

    QA SOPs QC SOPs Micro SOPs HVAC Production SOPs Stores SOPs Checklists Maintenance SOPs HPLC Sterile GLP Validation Protocols Water System GDP Regulatory Maintenance Calibration Warning Letters Education B.Pharmacy
    Online Courses


    Follow Pharmaguideline



    DOCUMENTS

    PHARMACEUTICAL DOCUMENTS




    Editable Pharmaceutical Documents in MS-Word Format. Ready to use SOPs, Protocols, Master Plans, Manuals and more...

    View


    adsbypg


    GET APP FOR NEWS UPDATES


    Android App