Terminal Sterilization of Sterile Pharmaceutical Preparations : Pharmaguideline
  •   Pharmaguideline Courses Enroll Now
  • May 2, 2016

    Terminal Sterilization of Sterile Pharmaceutical Preparations

    Learn the process of terminal sterilization of the sterile pharmaceutical products by moist heat, irradiation and ethylene oxide.
    Sterile pharmaceutical products, large volume parenterals and small volume parenterals are sterilized after the packing of the final products is known as terminal sterilization. The process is important to assure the sterility of the product.

    Terminal SterilizerAll parenterals, ophthalmic products and medical devices are subjected to terminal sterilization. Products are sterilized terminally in batches as they are manufactured. These products are not thermally sterilized during the manufacturing but sterilized by filtration. It reduces the risk of the non-sterile unit within the sterile product.

    Hold time period should be validated before the terminal sterilization process starts. It is important to maintain the product quality because microbial growth may occur during the storage before the terminal sterilization that can harm the product quality.


    There are following three methods of terminal sterilization:
    1. Moist Heat Sterilization
    2. Irradiation
    3. Ethylene Oxide

    Moist heat terminal sterilization is done by spraying hot water on the product units in the sterilizer. Steam is not used for sterilization because steam has a high temperature that can cause thermal degradation of the drug. Terminal sterilization is not always done at 121°C for 15 minutes but it changes as per the heat sensitivity of the product.

    But it is important to get desired F0 value by increasing the time of sterilization when we decrease the sterilization temperature. For example, if we sterilize a heat sensitive product at 108°C, sterilization time should increase to 60 minutes. All large volume parenterals (LVP), small volume parenterals (SVP) and ophthalmic products are terminally sterilized by the moist heat method.

    Irradiation and ethylene oxide are used for pre-filled syringes and other medical devices. Methods are also useful for the products those are highly heat sensitive.

    Loading pattern of the product units for terminal sterilization should be uniform in the chamber for proper sterilization of all units. Heat should be distributed throughout the chamber and should penetrate the product.

    Effect of terminal sterilization on product stability should be studied because it may degrade the product and may cause an adverse effect on the user. A safe and effective combination of temperature and time should be selected for terminal sterilization for heat sensitive products.

    Any of the methods can be used for terminal sterilization according to the product to be sterilized but terminal sterilization process should be validated as it is an important part of sterile manufacturing.

    1 comment: Post Yours! Read Comment Policy ▼

    1. Besttttttttttttttttttttttttttttttttttttttttttt............ language is veruy simple and veruy useful information

      ReplyDelete

    Please don't spam. Comments having links would not be published.


    Popular Categories

    QA SOPs QC SOPs Micro SOPs HVAC Production SOPs Stores SOPs Checklists Maintenance SOPs HPLC Sterile GLP Validation Protocols Water System GDP Regulatory Maintenance Calibration Warning Letters Education B.Pharmacy
    Online Courses


    Follow Pharmaguideline



    DOCUMENTS

    PHARMACEUTICAL DOCUMENTS




    Editable Pharmaceutical Documents in MS-Word Format. Ready to use SOPs, Protocols, Master Plans, Manuals and more...

    View


    adsbypg


    GET APP FOR NEWS UPDATES


    Android App