SOP for Control of Cross-contamination : Pharmaguideline
  •   Pharmaguideline Courses Enroll Now
  • May 1, 2013

    SOP for Control of Cross-contamination

    Standard operating procedure to control the cross contamination in batch during dispensing and manufacturing of product.

    1.0 OBJECTIVE

    To describe the procedure for controlling and preventing cross-contamination in the dispensing area during operations.

    2.0 SCOPE

    This procedure applies to the manufacturing facilities.

    3.0 RESPONSIBILITY

    Warehouse- Officer.

    4.0 ACCOUNTABILITY

    Warehouse- Asst. Manager.

    5.0 PROCEDURE

    Following controls are to be maintained in Dispensing area:
    5.1 Following the dress code for dispensing areas and always use hand gloves and nose mask while working.
    5.2 Ensure that the AHU’s is ON one hour before starting the activity by recording the pressure differential.
    5.3 Always clean and disinfect the area as per related SOP before start-up of the activity. Always clean and disinfect the floors, walls, ceiling, doors and other facilities as per the respective SOP.
    5.4 Check that the instrument being used is calibrated and within their valid date of calibration.
    5.5 Always put status label on all equipment and measuring instrument.
    5.6 Ensure that purified water is at the temperature not less than 80 °C through a continuous recirculation loop at the time of usage.
    5.7 Maintain the dispensing area at positive pressure.
    5.8 In the dispensing area provide adequate segregation for different materials and equipment.
    5.9 Keep the personnel traffic at the minimum in dispensing areas.
    5.10 Take line clearance every day before starting dispensing activity and after product or batch change over.
    5.11 Do the dispensing of all raw materials under the reverse airflow hood, started at least one hour before activity.
    5.12 Keep raw materials separately batch wise and with proper identification label on SS pallet.
    5.13 Label all sanitizing agents (70%IPA) purified water bottle with collection date and use before dates.
    5.14 Dispensed one material at a time.

    5.15 Sanitize washed equipment, utensils with freshly prepared 70% IPA solution, dry and covered with the clean polybag when not in use.
    5.16 Ensure that all the materials are opened and placed under reverse laminar airflow during dispensing activity.
    5.17 Clean the container outside then bring it in the dispensing room.
    5.18 Dispense one material at one time.
    5.19 Clean area after product change over.
    5.20 Ensure S.S.scoops, spatula, etc are clean and dry.

    6.0 ABBREVIATIONS

    6.1 SOP: Standard Operating Procedure
    6.2 AHU: Aur Handling Unit
    6.3 IPA: Isp Propyl Alcohol

    1 comment: Post Yours! Read Comment Policy ▼

    1. What action to be taken if the product is over dry during drying the wet material

      ReplyDelete

    Please don't spam. Comments having links would not be published.


    Popular Categories

    QA SOPs QC SOPs Micro SOPs HVAC Production SOPs Stores SOPs Checklists Maintenance SOPs HPLC Sterile GLP Validation Protocols Water System GDP Regulatory Maintenance Calibration Warning Letters Education B.Pharmacy
    Online Courses


    Follow Pharmaguideline



    DOCUMENTS

    PHARMACEUTICAL DOCUMENTS




    Editable Pharmaceutical Documents in MS-Word Format. Ready to use SOPs, Protocols, Master Plans, Manuals and more...

    View


    adsbypg


    GET APP FOR NEWS UPDATES


    Android App