1.0 Objective
To ensure the control over non-viable count in solid dosage form area at rest condition.2.0 Scope
To measure non-viable count of air in solid dosage form area at rest condition.3.0 Responsibility
3.1 Doing: Technical Assistant./Executive3.2 Checking: Executive/Manager
4.0 Accountability
Head of Department5.0 Procedure
5.1 Frequency of the testCover all operational area (“O” area) of solid dosage form once in a three month. ( 3 Months + 7 days )
5.2 Location chart for non-viable particle count of air in solid dosage area is attached.
5.3 Instrument Used:- Laser particle counter
5.4 Take air sample from a location near the concerned operation at its working height. Repeat and take two (2) such reading.
5.5 Sample the air at the rate of 1 ft3 for 1 min.
5.6 Operate the instrument as per S.O.P.
5.7 Record the results in the Annexure-I.
5.8 Acceptance criteria /ft3
Limits
6.2 ft3 = Feet cube
Class
|
Air particle count
|
Alert level
|
Action level
|
100
|
> 0.5µ
|
76 – 100
|
>100
|
> 5.0µ
|
Nil
|
Nil
| |
100,000
|
> 0.5µ
|
80,000 – 100,000
|
>100,000
|
> 5.0µ
|
400 - 560
|
>560
|
6.0 Abbreviations
6.1 µm = Micro meter6.2 ft3 = Feet cube
ANNEXURE – I
MICROBIOLOGY DEPT
NON VIABLE PARTICLE COUNT OF SOLID DOSAGE AREA
S.O.P.NO.-_________________
Test :- Non Viable Air Particle Count
| |
Location:-
| |
Sampling Point No.:-
|
Date of sampling:-
|
Instrument Id.No:-
|
Date of Report:-
|
Sampled area:- 1 ft3
|
Sample run time:- 1 minute
|
SR.No |
No. of readings
|
(Particle/ft 3)
| |
0.5 µ
|
5.0 µ
| ||
1
|
First reading
| ||
2
| Second reading | ||
Mean Value
|
Class
|
Air particle count
|
Alert level
|
Action level
| |
100
|
> 0.5 µ
|
76 – 100
|
> 100
| |
> 5.0 µ
|
Nil
|
Nil
| ||
100,000
|
> 0.5 µ
|
80,000 - 100,000
|
> 100,000
| |
> 5.0 µ
|
400 - 560
|
> 560
| ||
REMARKS: -
MICROBIOLOGIST
|
CHECKED BY
|
DATE
|
DATE
|