1.0 Objective
To lay down the procedure for systematic cleaning of entire Microbiology Laboratory.2.0 Scope
This procedure is applicable to carry out daily cleaning in the Microbiology testing laboratory area other than clean area.3.0 Responsibility
3.1 Doing: Housekeeping personnel3.2 Checking: Executive/Manager
4.0 Accountability
Head of the Department5.0 Procedure
5.1 SCHEDULEA. Floor, Wall & Platforms Area Morning: Use 0.1% solution of teepol or Mocidet M300 Afternoon : as below
Sr. No. Day Disinfectant is used
01 Monday 2.5% Dettol
02 Tuesday 10% Solution of Aldekol-H
03 Wednesday 1% Solution of (Chlorehexidine, Gluconate 7.5%v/v+Cetrimide 15.0%w/v)
04 Thursday 2.5% Dettol
05 Friday 10% Solution of Aldekol-H
06 Saturday 1% Solution of (chlorehexidine, Gluconate 7.5%v/v+Cetrimide 15.0%w/v) (Use Hexcita brand)
For Sunday working use 0.1% solution of cleaning agent (Teepol or Macidet M300 brand)
B. Racks of Incubators & other areas
Weekly: with 70% Isopropyl alcohol
C. Glass, Doors & Window Frames
Weekly: 1. With colin solution 2. With 70% isopropyl alcohol
D. Ceiling
Weekly: with 70% Isopropyl alcohol
E. Drawers under working tables
Once in a month with dry cotton cloth
F. Switches, furniture :
Once in a month with a dry cotton cloth.
5.1 Prepare required a quantity of cleaning solution using distilled water as per schedule mentioned in as above.
5.2 Clean the entire microbiology department using following equipment
1.Floor mops 2. Cloths & Sponge (non fibre shedding) 3. Ceiling mop (non particles shedding)
5.3 Following areas are to be cleaned.
1. Chemical testing room
2. Washing room
3. Media destruction room
4. Walk in incubators: 30°-35°C and 20°-25°C
5. Media preparation room
6. Office room
7. Lobby
8. Hot area
9. Store
5.5 At the end of shift drain the excess solution of cleaning agent in the drain line wash and dry the empty containers.
5.6 Mop the glasses with the help of glass wipers.
5.7 Record of cleaning record of the microbiology laboratory cleaning as per annexure.
Related: Microbial Resistance against Disinfectants
°C = Degree centigrade
% = Percentage
6.0 ABBREVIATIONS
LAF = Laminar Air Flow°C = Degree centigrade
% = Percentage
ANNEXURE
CLEANING RECORD OF MICROBIOLOGICAL LABORATORY
MICROBIOLOGICAL ANALYSIS ROOM
|
SUNDAY
DATE:
|
MONDAY
DATE:
|
TUESDAY
DATE:
|
WEDNESDAY
DATE:
|
THURSDAY
DATE:
|
FRIDAY
DATE:
|
SATURDAY
DATE:
|
1. Two times in a day (Floor/Wall/Platform) | |||||||
a. Chemical testing room | |||||||
Morning : | |||||||
Afternoon :
| |||||||
b. Washing room | |||||||
Morning : | |||||||
Afternoon : | |||||||
c. Media destruction room | |||||||
Morning : | |||||||
Afternoon : | |||||||
d. Incubator (20°C-25°C) & (30°C-35°C) | |||||||
Morning : | |||||||
Afternoon : | |||||||
e. Media preparation room | |||||||
Morning : | |||||||
Afternoon: | |||||||
f. Office room | |||||||
Morning : | |||||||
Afternoon : | |||||||
g. Lobby | |||||||
Morning : | |||||||
Afternoon : | |||||||
h. Store room | |||||||
Morning : | |||||||
Afternoon : | |||||||
i. Hot area | |||||||
Morning : | |||||||
Afternoon : |