1.0 Objective
To ensure the control over non-viable particle count in aseptic area.2.0 Scope
To measure non-viable particle count of air in the aseptic area.3.0 Responsibility
3.1 Doing: Tech.Assistant.(Microbiologist)/Executive3.2 Checking: Executive /Manager
4.0 Accountability
Head of the Department5.0 Procedure
Sampling room |
Room class
|
Frequency
| |
Insulin filling & Filtration room
|
Other than insulin area
| ||
Under PF module of Filling machine
Under PF module in Sterile Filtration room
|
100
100 | Three times in a weekThree times in a week |
Weekly once to coverall area once in a month
Weekly once to cover all area once in a month |
Sterile Filtration room Preparation room |
10,000
| Three times in a week during work |
Weekly once to cover room once in a month
|
Non sterile preparation & wash room |
100,000
|
Weekly once to cover room once in a month
|
6.0 ABBREVIATIONS
6.1 SOP - Standard Operating Procedure